Features
Overview
Technical
Datalogger
Memory Non-volatile flash memory
Power Two 9 VDC alkaline batteries (inc.)
Battery Life Up to 1 year
Moisture Protection Protective coating (helps prevent damage to electronics from condensation)
Temperature -40° +85°C
Humidity 0-95% non-condensing
Storage Capacity 81,759 time/date stamped datapoints (including battery voltage)
Recording Rate High Speed (10 samples per second), Fixed Interval (programmable from 1 second to >1 year), Logarithmic, Exception
Data Overwrite Select memory wrap or unwrap (unwrap will stop logging once memory is full)
Clock 0.0025% or 1 minute in 1 month
Enclosure Vented 4.8 cm dia. x 29.2 cm Stainless steel, UV protected PVC
Weight 0.7Kg with battery and cable
Communication WL16S: RS-232 4-pin circular conn. WL16U: USB Type B Selectable Baud Rates: 9600, 19200, 28800, 38400, 57600, 115200
Certificates CE Compliance
Software Global Logger II Software (inc)
Features Tabular Display/Printout; data in standard spreadsheet format (CSV); programmable alarm start and stop times; field calibration and help files included
Cable
Conductors 4 each 22 AWG
Material Marine grade polyether jacket, polyethylene vent tube, full foil shield
Shield Aluminum Mylar
Outside Diameter 0.78 cm
Length Standard 7.62m upto 610m
Sensor
Sensor Element Silicone Diaphragm, Wet/Wet Transducer
Ranges (ft) 0.9m, 2.7m, 9m, 18m, 36m, 76m, 152m
Linearity and Hyteresis ±0.1% full scale
Accuracy ±0.1% full scale at constant temperature
Overpressure Not to exceed 2x full scale range
Warm-Up Time 3 seconds recommended
Compensation dynamic temperature compensation -1.1 to 21.1°C, automatic barometric pressure compensation
Housing Material 304L stainless steel
Housing Size 2cm dia. X 14 cm L, small enough for a 1 inch well. Titanium option has 1 inch diameter.
Bluetooth Adapter
Format Bluetooth 2.0 SPP (Serial Port Protocol)
Baud Rate Auto Detect up to 115K Baud
Power 9V Alkaline. 20 hrs continuous use
Current 30mA Average
Range 6.1 m maximum
Operating Temp -40° +85°C
Documents