U3000/U4000 Ultraflo Clamp-on Flow Meter

 

U3000_U4000 Ultraflo Clamp-on Flow Meter 480x393

 

 

 

Features

  • Flow Range – 0.1m/sec to 20m/sec bi-directional
  • Clamp-on Sensors
  • Easy to install
  • DSP measurement technique
  • Display – 64 x 240 pixels graphic display
  • Programming is password protected via 15 key control panel
  • Power – 86v to 264v AC. Optional 24V a.c./d.c. 1A max
  • 9 user selectable languages
  • Accuracy +/- 0.5% to +/- 3% depending on pipe size for flow rate > 0.2m/s
  • CE Approved
  • Reynolds number correction

Overview

The U3000/4000 Ultraflo brings simplicity to the non-invasive measurement of liquid flow, offering the user quick and accurate flow measurement with its easy to follow menu and simple set up. A cost-effective alternative to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability! Compact, rugged and reliable, the Ultraflo has been designed to provide sustained performance in industrial environments.

The Ultraflo is a transit time ultrasonic flow meter designed to work with clamp-on transducers, to provide accurate measurement of liquid flowing within a closed pipe, without the need for any mechanical parts to be inserted through the pipe wall or to protrude into the flow system. It takes just a few minutes to install and there is no need to shut down flow or drain the system! When ultrasound is transmitted between the transducers, the speed at which the sound travels through the liquid is accelerated slightly by the velocity of the liquid through the pipe. When ultrasound is
transmitted in the opposite direction, the flow of the liquid causes the transmitted sound to decelerate. The subsequent time difference is directly proportional to the flow velocity in the pipe. Having measured the flow velocity and knowing the pipe cross-sectional area, the volumetric flow can be easily calculated.

Technical

GENERAL
DSP Measurement Technique Transit time.
Timing Resolution 50 pico-second, continuous signal level indication on display.
Flow Velocity Range Minimum Velocity 0.1m/s; Max Velocity 10m/s Bi-directional.
Turn Down Ratio200:1
Accuracy ±0.5% to ±2% of flow reading for flow rate >0.2m/s and Pipe OD >75mm.
±3% of flow reading for flow rate >0.2m/s and Pipe OD in range 13mm - 75mm.
±6% of flow reading for flow rate < 0.2m/s.
Repeatability ±0.5% of measured value or ±0.02m/s whichever is the greater.
Reynolds Number Correction Flow velocity corrected for Reynolds number over entire velocity range.
Response Time < 500ms depending on pipe diameter.
Selectable Flow Units Velocity: m/sec, ft/sec.
Volume: l/s, l/min, l/h, gal/s gal/min, gal/h, USgals/s, USgals/min, USgals/h, Barrel/h,
Barrel/day, m³/s, m³/min, m³/h.
Selectable Volume Units litres, m³, US gallons, gallons, barrels (oil).
Total Volume 12 Digits - forward and reverse.
APPLICABLE FLUID TYPES
Fluid Condition Clean liquids or oils that have less than 3% by volume of particulate content. Applications
include river water, sea water, potable water, demineralised water, glycol/water mix,
hydraulic systems and diesel oil.
APPLICABLE PIPE TYPES
Pipe Materials Any sonic conducting medium such as Carbon Steel, Stainless Steel, Copper, UPVC,
PVDF, Concrete, Galvanised Steel, Mild Steel, Glass, Brass. Including Lined Pipes - Epoxy,
Rubber, Steel, Plastic.
Pipe Dimension (outside diameter) Min 13mm; Max 5000mm (with ‘D’ sensor set).
Pipe Wall Thickness 1mm - 75mm.
Pipe Lining Applicable pipe linings include Rubber, Glass, Concrete, Epoxy, Steel.
Pipe Lining Thickness 0mm – 25mm.
Pipe Wall Temperature Range Standard sensor operating temperature is -20°C to +135°C.
EnclosureThe U3000/U4000 enclosure is IP65 rated.
Optional TransducersFor pipes 1500mm up to 5000mm contact Micronics.
Transducer Operating Temp -20°C to +135°C.
Optional Hi-Temp20°C to +200°C.
OutputsOpto Isolated 0/4 –20mA; RS 232/USB (U4000 ONLY);
Pulse Output Programmable Pulse Width from 2ms - 500ms or frequency pulse.
Two programmable AlarmsHigh/Low flow, Volume or error.
Data Logger (U4000 ONLY)Built in data logger with 200,000 data points
Portagraph Software (U4000 ONLY)

Documents